time发布时间:2020-07-21 10:08
visit阅读:152 次
Device module wiring diagram
Device module wiring diagram
Wiring instructions:
① Line is setThe line is the Trident grounding wire of equipment power supply;
②[1.5m2 yellow-green] wire is the grounding wire between the equipment module and the protective ground (the internal common ground)
③ [1.5m2 yellow green] line is the grounding wire between equipment and protective ground
④ [1.5m2 Yellow green] line is the detection line between equipment and equipment module
Description of open circuit alarm:
① If the line is disconnected, the buzzer will not alarm if the line is not disconnected;
① If the line is not disconnected, ② the line is disconnected and the buzzer does not alarm;
①The line is disconnected, ②The line is disconnected, the buzzer will alarm;
③Line/④Line If any line is disconnected, the buzzer will alarm.

Wiring diagram of table cushion module
Device module wiring diagram
Wiring Description:
①[1.0m2 green] wire is the ground wire between the pad module and the electrostatic ground (the internal ground is common)
②[1.0m2green] line is the grounding wire (1M) between the pad and the electrostatic ground
③[1.0m2green] line is the detection line between table mat and table mat module
Description of open circuit alarm:
①Line disconnection alarm status:
Situation 1: The table mat is placed on a conductive table, and the conductive table is not grounded, ① the line is disconnected and the buzzer will alarm
Situation 2: The table mat is placed on a conductive table, and the conductive table is grounded. ① The buzzer does not alarm when the wire is disconnected
Situation 3: The table mat is placed on a non-conductive table, and the line is disconnected and the buzzer will alarm
②line/③line disconnection, buzzer alarm

Wiring diagram of wrist strap module
Wiring diagram of wrist strap module
Wiring Description:
①/②[1.0m green] wire is the grounding wire between the wrist strap module and the electrostatic ground
③[8 Pin flat] line is the connection line between the wristband module and the wristband socket
Description of open circuit alarm:
①/②The main ground or detection ground is disconnected, and the buzzer will alarm
③The connection line is broken and the buzzer will alarm

Equipment, table mat. Schematic diagram of mixed wiring of human body module
Equipment, table mat. Schematic diagram of mixed wiring of human body module
Wiring Description:
①The wire is the three-prong ground wire of the equipment power supply;
②The [1.0m2 green] line is the grounding wire between the pad, the wrist strap module and the electrostatic ground (the internal ground is common)
③[1.0m2green] line is the detection line between the wrist strap module and the electrostatic ground
④[1.5m2 yellow-green] wire is the grounding wire between the equipment module and the protective ground
⑤[1.5m2 yellow-green] wire is the grounding wire between the equipment and the protective ground
⑥[1.5m2 yellow-green] line is the detection line between equipment and equipment module
⑦[1.0m2green] line is the grounding wire between the pad and the electrostatic ground (1M)
⑧[1.0m2green] line is the detection line between the table mat and the table mat module
⑨[8 Pin flat] line is the connection line between the wristband module and the wristband socket